3.2.9 Reboot
Sincecellularnetworkisnotasstableasfixedline,M1000Prosupportsvariousautorebootfunctiontokeepmodem
working24x7withouthangup.
Reboot
Note:Thisfunctionisavailableunderboth“ConfigMode”and“NormalMode”.
Item Description Default
Time
TicktheTimecheckboxtoallowmodemautorebootwithpresettime
schedule every day, support maximum 3 time schedule/day (e.g.
07:00,11:00and23:30everyday).
Disable
Call
TicktheCallcheckboxtoallowmodemautorebootwithincomingcall
fromspecifiedCallerID(phonenumber).
The Caller ID (phone number) should be specified in Phone Book
tabbyinputtingthephonenumberandtickCallRebootcheckbox.
Disable
EnableSMSReply
TicktheEnableSMSReplycheckboxtoallowmodemsendreplyshort
message after auto reboot by Call Reboot from specified Caller ID
(e.g.Rebootok!).
Note:Onlysupportte xtformatSMS.
Disable
SMS
Tick the SMS checkbox to allow modem auto reboot with incoming
specifiedshortmessagefromspecifiedCallerID(phonenumber).
SpecifiedshortmessageissetatPassworditem.(e.g.reboot)
The Caller ID (phone number) should be specified in Phone Book
tabbyinputtingthephonenumberandtickSMSRebootcheckbox.
Disable
EnableSMSReply
TicktheEnableSMSReplycheckboxtoallowmodemsendreplyshort
message after auto reboot by SMS Reboot from specified Caller ID
Disable