3.2.12 Wakeup
M1000 Pro V2 supports various dial-up policies, wakeup at preset time, wakeup periodically, wakeup by Call, wakeup
by SMS, wakeup by local serial port data. In this page, user can set up different wakeup policies.
Wakeup
Note: This function is available under Normal Mode.
Item
Description
Default
Time
Tick Enable to allow gateway automatically connects to GPRS/UMTS
with preset time schedule every day, support maximum 3 time
schedule/day (e.g. 07:00, 11:00 and 23:30 every day).
Disable
Periodical
Tick Enable to allow gateway automatically connects to GPRS/UMTS
with preset interval, select from 1 to 1800 minutes. The interval is
defined as time interval between two GPRS/UMTS connections.
Disable
Call
Tick Enable to allow gateway automatically connects to GPRS/UMTS
with incoming call from specified Caller ID (phone number).
Disable
Phone Group @ Call
Set the Phone Group which was allowed to wake up the gateway by