Robustel GoRugged R3000 Lite User Guide
RT_UG_R3000 Lite_v.1.0.0 23.12.2013 41 / 113
Confidential
When Select Protocol “Modbus”:
When Select Protocol “Transparent Over Rlink”:
When Select Protocol “Modbus Over Rlink”:
RS485 @ Serial
Item
Description
Default
Baud-rate
Select from “300”, “600”, “1200”, “2400”, “4800”, “9600”, “19200”, “38400”,
“57600” , “115200”and “230400”.
115200
Data bit
Select from “7” and “8”.
8
Parity
Select from “None”, “Odd” and “Even”.
None
Stop bit
Select from “1” and “2”.
1
Protocol
Select from “None”, “Transparent” and “Modbus”.
Transparent: Router will transmit the serial data transparently without any
Transparent